Auto Coding Blood Sugar Test Tool
Group: Middle-aged and Old
Certification: CE
Glucose Oxidase electrode measurement method of Auto Coding Blood Sugar Test tool:
Principle: Blood glucose is measured by measuring the amount of current produced by the reaction between glucose in the blood and glucose oxidase in the test paper.
Advantages: Compared with the biochemical analyzer and chemical method, the measurement is faster (within 30 seconds), and the blood volume is less (5 microliters or less).
Specification
1)Result in only 8 seconds
2)Less than 1ul blood sample
3)Automatic shut-off in 3 minutes
4)180 test memory
5)1,7,14,21,28-days average display
6)Auto coding
7)Sample Size 0.8ul
8)Measuring Range 8 seconds
9)Acceptable hematocrit range 25%-65%
10)Memory Capacity 180 test results with time/date
11)Automatic shut-off In 3 minutes
12)Altitude 8800 feet (2750meter)
13)Test result Plasma glucose
14)Assay method electrochemical biosensor
disinfect
It should be emphasized that iodine-containing disinfectants (such as iodophor, iodine) should not be used to disinfect the skin. The blood glucose monitoring system using the principle of glucose oxidase (including the blood glucose meter based on the electrode method and photochemical method), the iodine in iodine and iodophor can react with the enzyme in the blood glucose test paper and cause errors. This is because the blood glucose meter based on the electrode method principle is that when whole blood is dripped into the reaction area of the test strip, the blood glucose in the sample reacts with the chemical substrate (enzyme) to generate an electric current, and the blood glucose is calculated by detecting the intensity of the electric current content. Iodine and enzymes can also react, thereby interfering with the value of the current and causing deviations in blood sugar. The blood glucose meter based on the principle of photochemical method reflects the blood glucose level by detecting the color change of the test strip during the reaction process. Iodine can interfere with the color change through the above chemical reaction and its own color, thereby affecting the accuracy of the blood glucose level.
Test attention of using Auto Coding Blood Sugar Test tool
① Try to be at room temperature;
②Avoid placing the instrument near electromagnetic fields (such as mobile phones, microwave ovens, etc.);
③The amount of blood collected should not be too much or too little.